Installation Instructions Y75
Issue Date August 22, 2008
© 2008 BASO Gas Products 1
Part No. BASO-INS-Y75, Rev. B www.baso.com
Dimension “B”
Locating
Dimension
Dimension “A”
Electrode
Protrusion
Length
Figure 1: Y75 Sensing Probe
The Y75 sensing probe may be used to replace broken or damaged sensing
probes in electronic ignition control systems.
Table 1: Specifications
Product
Y75 Replacement Sensing Probes
Material
Rod: Kanthal D or Hoskin 815
Ceramic: Steatite
Maximum
Rod:
1,800°F (982°C)
Temperature
Ceramic:
1,000°F (538°C)
Agency Listings
CSA Certificate Number 22951-165071
Specification Standards
ANSI Z21.20, CAN1-6.4
Performance specifications are nominal and conform to acceptable industry standards. All agency
certification of BASO products is performed under dry and controlled indoor environmental conditions.
Use of BASO products beyond these conditions is not recommended and may void the warranty.
Product must be protected if exposed to water (dripping, spraying, rain, etc.) or other harsh
environments. The original equipment manufacturer or end user is responsible for the correct
application of BASO products. Consult BASO Gas Products LLC for questionable applications. BASO
Gas Products LLC shall not be liable for damages or product malfunctions resulting from
misapplication or misuse of its products.
Refer to the Y75 Series Sensing Probes Product Bulletin (BASO-PB-Y75) for necessary information on
operating and performance specifications of this product.
!
CAUTION: Turn off the gas to the appliance at the upstream
manual shutoff valve before installing the Y75 sensing
probe.
!
WARNING: Shock Hazard. To prevent electrical shock or possible
damage to the equipment, disconnect the power
supply.
Series Y75 Sensing Probes
for Electronic Ignition Systems
Application
Installation
Vue de la page 0
1 2

Résumé du contenu

Page 1 - Series Y75 Sensing Probes

Installation Instructions Y75 Issue Date August 22, 2008 © 2008 BASO Gas Products 1 Part No. BASO-INS-Y75, Rev. B www.baso.com Dimensi

Page 2 - PO Box 170

2 Series Y75 Replacement Sensing Probe for Electronic Ignition Systems Installation Instruction Perform the following procedure to install the Y75

Commentaires sur ces manuels

Pas de commentaire