Baso Y71 Manuel d'utilisateur Page 2

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 2
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 1
2 Y71 Regulator Conversion Kits Installation Instructions
To install the Y71 conversion kit into the gas valve:
1. Shut off the gas supply at the main manual
shutoff valve.
2. Change the orifices of the main burner and the
pilot burner to those recommended by the
appliance manufacturer.
3. Remove the outlet pressure tap plug from the
valve or manifold down stream of the valve and
install a manometer.
4. Remove Seal Screw A, Adjustment Screw B, and
Regulator Spring C from the regulator stack
(Figure 1).
IMPORTANT: Do not reuse the seal screw or
the regulator spring. However, the adjustment screw
may be reused. Note that the new seal screw and
regulator spring must be installed for proper
regulation.
5. Insert the new regulator spring, supplied in the
kit, into the regulator stack. Use care when
handling to avoid deforming the spring.
6. Reinstall the adjusting screw into the regulator
stack.
7. Turn on the gas supply and set the thermostat to
the highest setting.
8. Adjust the regulator to the manufacturer’s
specified setting by turning the adjusting screw in
the regulator stack. Turn clockwise to increase
and counterclockwise to decrease.
9. After the regulator adjustment is completed and
rechecked, install the new seal screw into the
regulator stack. Recheck setting.
10. Turn off the gas supply and set the thermostat to
Off or the lowest setting. Disconnect the
manometer and reinstall the pressure tap plug.
IMPORTANT: Place the adhesive-backed
Caution label on the visible side of the valve, making
sure the product label on the valve is not covered.
11. Using a felt-tipped pen, change the setting on the
label, located on the valve adjacent to the
regulator stack, to the new regulator setting
12. Turn on the gas supply and check for gas leaks
using a soap solution.
13. Perform the Checkout section before leaving the
installation.
Setup and Adjustments
Checkout
!
WARNING: Risk of Explosion or Fire.
Follow this or an equivalent checkout procedure
after installation. Before leaving the installation,
verify that the gas valve functions properly and that
the system has no gas leaks. Gas leaks can lead to
an explosion or fire, and may result in severe
personal injury or death.
Make sure all components are functioning properly by
performing the following test.
1. Open the main manual shutoff valve.
2. Test all joints and connections for leaks with a
soap solution.
3. Close the main manual shutoff valve and wait at
least 5 minutes for unburned gas to escape from
the appliance, and then reopen the shutoff valve.
4. Turn on the main electrical power switch and
close the thermostat contacts. The appliance
should operate in accordance with the
manufacturer’s specified sequence of operation.
5. Turn the thermostat to a low dial setting to open
the contacts. All burner flames should be
extinguished. Repeat Steps 3 and 4 at least three
times.
6. Return the thermostat to a normal setting before
leaving the installation.
Performance specifications are nominal and conform to acceptable industry standards. All agency certification of BASO products is performed
under dry and controlled indoor environmental conditions. Use of BASO products beyond these conditions is not recommended and may void
the warranty. Product must be protected if exposed to water (dripping, spraying, rain, etc.) or other harsh environments. The original
equipment manufacturer or end user is responsible for the correct application of BASO products. Consult BASO Gas Products LLC for
questionable applications. BASO Gas Products LLC shall not be liable for damages or product malfunctions resulting from misapplication or
misuse of its products.
Refer to the Y71/GM-70 Regulator Conversion Kits Product Bulletin (BASO-PB-Y71/GM) for necessary information on operating and
performance specifications for this product.
1007 South 12th Street
PO Box 170
Watertown, WI 53094 www.baso.com
1-877-227-6427 (1-877-BASOGAS) Published in U.S.A.
Vue de la page 1
1 2

Commentaires sur ces manuels

Pas de commentaire